M16 IP67

Female angled connector, shielded

back

Series 425

Number of contacts

Variant 5

Contacts: 5, cable: 5 x 0.25 mm², female angled connector, shielded

Ordering number 79 6314 200 05
Connector locking system bolted
Termination solder, moulded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable outlet -
Cable length 2 m
Degree of protection IP67
Upper temperature 70 °C
Lower temperature -25 °C
Rated voltage 250 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category I
Material group III
Rated current (40°C) 3 A
Volume resistivity ≤ 3 mΩ
Material of contact CuSn (Bronze)
Contact plating Au (gold)
Material of contact body PBT (UL 94 V-0)
Material of housing PUR
Cable data
material housing PUR
Insulation single lead PE
Single lead structure 14x0,15 mm
Cable sheath Ø 5.3
Bending radius cable fixed 53 mm
Bending radius cable movable 80 mm
Cable diameter 5.3
Variant 6 DIN

Contacts: 6 DIN, female angled connector, shielded, cable 6 x 0.25 mm²

Ordering number 79 6318 200 06
Connector locking system bolted
Termination molded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable length 2 m
Degree of protection IP67
Upper temperature 70 °C
Lower temperature -25 °C
Rated voltage 250 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category I
Material group III
Rated current (40°C) 3 A
Volume resistivity ≤ 3 mΩ
Material of contact CuSn (Bronze)
Contact plating Au (gold)
Material of contact body PBT (UL 94 V-0)
Material of housing PUR
Cable data
material housing PUR
Insulation single lead PVC
Single lead structure 14 x 0,15 mm
Cable sheath Ø 5.3
Temperature range cable movable °C from -5
Temperature range cable movable °C to 70
Temperature range cable fixed °C from -20
Temperature range cable fixed °C to 70
Bending radius cable fixed 53 mm
Bending radius cable movable 80 mm
Variant 8 DIN

Contacts: 8 DIN, cable: 8 x 0.25 mm², female angled connector, shielded

Ordering number 79 6372 200 08
Connector locking system bolted
Termination solder, moulded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable outlet -
Cable length 2 m
Degree of protection IP67
Upper temperature 70 °C
Lower temperature -25 °C
Rated voltage 60 V
Rated impulse voltage 500 V
Pollution degree 1
Overvoltage category I
Material group III
Rated current (40°C) 3 A
Volume resistivity ≤ 3 mΩ
Material of contact CuSn (Bronze)
Contact plating Au (gold)
Material of contact body PBT (UL 94 V-0)
Material of housing PUR
Cable data
material housing PUR
Insulation single lead PVC
Single lead structure 19x0,13 mm
Cable sheath Ø 6
Bending radius cable fixed 60 mm
Bending radius cable movable 90 mm
Variant 12

Contacts: 12, cable: 12 x 0.25 mm², female angled connector, shielded

Ordering number 79 6330 200 12
Connector locking system bolted
Termination solder, moulded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable outlet -
Cable length 2 m
Degree of protection IP67
Upper temperature 70 °C
Lower temperature -25 °C
Rated voltage 60 V
Rated impulse voltage 500 V
Pollution degree 1
Overvoltage category I
Material group III
Rated current (40°C) 3 A
Volume resistivity ≤ 3 mΩ
Material of contact CuSn (Bronze)
Contact plating Au (gold)
Material of contact body PBT (UL 94 V-0)
Material of housing PUR
Cable data
material housing PUR
Insulation single lead PE
Single lead structure 14x0,15 mm
Cable sheath Ø 7.8
Bending radius cable fixed 78 mm
Bending radius cable movable 117 mm
Cable diameter 7.8